Polystone P Homopolymer UV Polypropylene Sheet
Polystone® P Homopolymer is a strong and stiffer material than copolymer PP, suitable for Australian climates. Ideal for chemical, corrosive, and heat environments, weldable for tank construction.
Specifications
- Minimum Operating Temperature
- 0°C
- Maximum Operating Temperature
- 100°C
- Food Grade
- Yes
- Drinking Water Approved
- No
- Tensile Strength (MPa)
- >30
- Thermal Expansion (µm/m.K)
- 120-190
- Coefficient of Friction
- N/A
- Chemical Resistance
- High
- Formats Available
- Rod, Sheet
Request a Quote
Polystone® P grey UV polypropylene homopolymer
Product characteristics
- High rigidity
- Very good weldability
- High chemical and corrosion resistance
Product applications
- Chemical engineering and tank building
- Ventilation technology
- Pump engineering
General properties
| Property | Test method | Unit | Guideline value |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g/cm³ | > 0.90 |
| Water absorption | DIN EN ISO 62 | % | < 0.1 |
| Flammability (thickness 3 mm / 6 mm) | UL 94 | HB |
Mechanical properties
| Property | Test method | Unit | Guideline value |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | > 30 |
| Elongation at break | DIN EN ISO 527 | % | > 50 |
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | > 1500 |
| Notched impact strength | DIN EN ISO 179 | kJ/m² | > 4 |
| Shore hardness | DIN EN ISO 868 | scale D | > 70 |
Thermal properties
| Property | Test method | Unit | Guideline value |
|---|---|---|---|
| Melting temperature | ISO 11357-3 | °C | 162 ... 167 |
| Thermal conductivity | DIN 52612-1 | W/(m*K) | 0.20 |
| Thermal capacity | DIN 52612 | kJ/(kg*K) | 1.70 |
| Coefficient of linear thermal expansion | DIN 53752 | 10⁻⁶/K | 120 ... 190 |
| Service temperature, long term | Average | °C | 0 ... 100 |
| Service temperature, short term (max.) | Average | °C | 150 |
| Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 90 |
Electrical properties
| Property | Test method | Unit | Guideline value |
|---|---|---|---|
| Dielectric constant | IEC 60250 | 2.4 | |
| Dielectric dissipation factor (10⁶ Hz) | IEC 60250 | 0.00019 | |
| Volume resistivity | DIN EN 62631-3-1 | Ω*cm | > 10¹⁴ |
| Surface resistivity | DIN EN 62631-3-2 | Ω | > 10¹⁴ |
| Dielectric strength | IEC 60243 | kV/mm | > 40 |
The data stated above are average values ascertained by statistical tests on a regular basis. They are in accordance with DIN EN 15860. The data above are provided purely for information and shall not be regarded as binding unless expressly agreed in a contract of sale.